EH stainless steel horizontal class electric pump

EH Horizontal Multistage Pumps

The EH Series, multistage booster pump is designed to meet your pressure boosting needs. The stainless steel construction offers high performance in a wide variety of applications. The EH Series is offered in five flow rates and different horsepower sizes in 1-phase or 3-phase to make sure you have the right pump to fit your application.

Features

  • Compact close coupled design, robust and corrosion resistant
  • Superior efficiency and performances
  • WRAS and ACS approved
  • Flexible application base plate
  • Floating neck ring in PPS
  • Heavy duty oversize motor shaft
  • Impellers and diffusers are made of stainless steel in order to achieve durability
  • Easy maintenance
  • Mechanical seal Type E0 = Carbon graphite / Ceramic alumina / EPDM: EH 3-5-9, EHsp 3-5
  • Mechanical seal Type E1 = Carbon graphite / Silicon carbide / EPDM: EH 15-20

Pump Specifications

  • Flow:
  • up to 29 m³/h at 50 Hz
  • up to 30 m³/h at 60 Hz
  • Head:
  • up to 104 m at 50 Hz
  • up to 111 m at 60 Hz
  • Connections: Rp threaded for inlet and outlet
  • Maximum working pressure: 10 bar
  • Maximum allowable amount of sand: 50 g/m³
  • Maximum ambient temperature: 40 °C
  • Liquid temperature range:
  • Minimum: from -15 °C to -10 °C according to gasket material
  • Maximum: +90 °C for domestic use (uses covered by CEI EN standard 60335-2-41); +110 °C only for industrial use (uses other than those covered by CEI EN standard 60335-2-41)
  • The hydraulic characteristics are guaranteed, according to ISO standard 9906:2012, grade 3B

Motor Specifications

  • Single-phase
  • Three-phase motor efficiency class IE3
  • Asynchronous, TEFC (totally enclosed, fan-cooled)
  • 2 pole
  • IP55 protection motor, insulation class F
  • Standard voltage
  • Single-phase:
  • 220-240 V ± 5% at 50 Hz (Thermal protection built into the motor)
  • 220-230 V ± 5% at 60 Hz (Thermal protection built into the motor)
  • Three-phase:
  • 220-240 V / 380-415 V ±5 % up to 3 kW at 50 Hz (Thermal protection to be provided into the starter panel by the installer)
  • 380-415 V / 660-690 V ±5 % from 4 kW at 50 Hz (Thermal protection to be provided into the starter panel by the installer)
  • 220-230 V / 380-400 V ±5 % up to 3 kW 60 Hz (Thermal protection to be provided into the starter panel by the installer)
  • Frequency of starts:
  • Max. 60 starts/hour for motor power up to 3 kW (with min. 1 minute resting time)
  • Max. 30 starts/hour for motor power from 4 kW (with min. 2 minute resting time)