Irrigation pumping stations
-
Drainage pumping stations
-
Stormwater pumping stations
-
Water pollution control
-
Flood control
Amacan K Benefits
-
Three-phase motor and optimum motor cooling by fluid handled make for efficient power utilisation.
-
The pump’s own weight ensures self-centring seating in the discharge tube, and an O-ring seals it; quick to install or remove.
-
The slim motor minimises discharge tube flow losses.
-
High reliability thanks to bearing temperature monitoring, vibration sensor, thermal motor protection, leakage sensors in the motor space and connection space as well as leakage monitoring of the mechanical seal system.
-
Low-vibration hydraulic system; inlet ribs and optimised bellmouth for vortex-free inflow.
-
Absolutely water-tight resin-sealed cable entries prevent any water from entering the motor – even in the event of a damaged cable.
Technical Data
Function:Pump
Connection type:Without
Drive concept:With electric actuator
Pump Max. flow rate:7200 m³/h
Min. flow rate:0.1 m³/h
Max. head:30 m
Pump Min. head:0.1 m
Mains frequency:50 Hz,60 Hz
Mains voltage:380 V,400 V,690 V
Casing material:EN-GJL-250
Nominal pressure:PN 16
Pump Max. allowed working pressure:16 bar
Suction behaviour:Non-self-priming
Max. allowed fluid temperature:40 °C
Pump Min. allowed fluid temperature:2 °C